Arc-faults have long been recognized as a significant hazard, responsible for a substantial number of electrical fires. These arcs, resulting from poor contact between conductors, can generate extremely high temperatures, making them a leading cause of electrical fires. In the United States, it is estimated that arc faults contribute to 50-75% of all electrical home fires, underscoring the urgent need for effective detection and prevention measures.

One common strategy for detecting arc faults is the use of arc-fault circuit interrupters, designed to cut off power when a low-voltage arc-fault is detected. However, these devices can sometimes suffer from false alarms, as certain electrical appliances produce waveforms similar to those of actual arc faults.

To address this challenge, Professor Yoshikazu Koike from the Shibaura Institute of Technology in Japan, in collaboration with Mr. Sittichai Wangwiwattana from the University of the Thai Chamber of Commerce (UTCC), have delved into the fundamental causes of arc faults. Their research has unveiled crucial insights into the nature of these faults, shedding new light on how they manifest and how they can be accurately detected.

In a breakthrough study, the team discovered that arc faults occur exclusively between copper-based conductors at elevated temperatures, with non-copper conductors exhibiting a different phenomenon characterized by a red glow. This distinction in behavior led the researchers to redefine the nature of arcs in alternating current systems, highlighting the critical role of copper-based connections in arc fault occurrences.

Building on their experimental findings, the researchers have now developed advanced simulations that mimic the arc-fault state observed in their previous tests. By analyzing current and voltage waveforms at different load values, they have identified a unique ‘current shoulder’ waveform associated with arc faults involving copper contacts. This distinctive waveform, detected by a current transformer, shows promise as a reliable indicator of impending arc faults, offering a potential solution for early detection and prevention.

The implications of this research extend beyond theoretical insights, paving the way for practical applications in enhancing electrical fire safety. The utilization of current transformers for detecting arc faults in low-voltage alternating current systems represents a significant advancement in mitigating the risks posed by these hazardous events.

As Prof. Koike emphasizes, this achievement holds immense potential for preventing low-voltage electrical fires, particularly in regions like Japan where such incidents are prevalent. By identifying and addressing arc faults more effectively, the research team’s work marks a significant step towards safeguarding homes and properties from the devastating impact of electrical fires.